The Pumproom
The Pumproom
Data of the pumping system
- The He3 pumps
- 8 roots blowers in series
- Pumping speed at the intake
- 13500m3/h
- Operating pressure at the Still
- 0.2 mbar at the lowest flow of 30 mmol/s and 1.2 mbar at 200 mmol/s
- The pumping line to the cryostat
- 20 m long, 320 mm in diameter.
- Total pressure drop from the still to the intake of the roots pump
- At a flow rate of 200 mmol/s the pressure drop is about 0.4 mbar across both the 320 mm line and the heat exchangers above the still.
- Gas purification
- To ensure trouble free operation, charcoal traps at room temperature and at 77 K are used to filter out impurities in the 3He return flow, in addition to the internal gas purification filters of the pumps.
- The 4He evaporator pump
- A Root's blower followed by a rotary pump
- Pumping speed of the 4He pump
- 2000 m3/h, maintaining the evaporator at 1.5 K. The cavity cooling line is connected directly to the rotary pump.
- Amount of helium gas in the refrigerator (total amount of mixture)
- 8600 liters of NTP helium gas.
- Amount of pure 3He
- 1070 liters NTP.