Gasesfor the COMPASS detectors(Run 2002) |
Flammable gases in red. Please send corrections.
Gases for COMPASS Detectors (7.6.2002) | ||||||||
detector | modules | gases | mixture | volume | typical flow | consumption | running cost total (splitted) | comments |
% | l | l/h | l/h | CHF/d | ||||
MicroMegas | 12 | Ne / C2H6 / CF4 | 80 /10 / 10 | 12 | 12 | 9.6 / 1.2 / 1.2 | 35.63 ( 26.33 / 0.4 / 8.90 ) | |
DC Saclay | 2 | Ar / C2H6 / CF4 | 45 / 45 / 10 | 1000 | 16 | 7.2 / 7.2 / 1.6 | 14.43 ( 0.26 / 2.93 / 11.78 ) | installation of DC3 scheduled for mid June '02 |
MWPC | 14 | Ar / CF4 / CO2 | 74 / 20 / 6 | 1955 | 760 | 26 / 7 / 2 | 52.56 ( 0.94 / 51.54 / 0.08 ) | closed circuit; without W45 yet (consumption and running cost will probably increase by ca. 30%) |
A | 7 | 1225 | 410 | one additional chamber installed | ||||
A* | 1 | 190 | 50 | |||||
B | 6 | 540 | 300 | |||||
W45 | 2 | ? | ~100 | included in MWPC gas system | ||||
GEMs | 10 | Ar / CO2 | 70 / 30 | 18 | 40 | 26 / 11 | 1.39 ( 0.94 / 0.45 ) | |
Straws | 1 1) | Ar / CF4 / CO2 | 74 / 20 / 6 | 350 | ? | 45 / 12 / 4 | 90.15 ( 1.62 / 88.36 / 0.17 ) | closed circuit; installation of 1 additional submodule planned |
MW1 | 2 | Ar / CO2 | 70 / 30 | 3000 | 125 | 60 / 50 | 4.22 (2.16 / 2.06) | |
MW2 | 6 | Ar / CH4 | 75 / 25 | 1800 | 240 | 180 / 60 | 38.72 ( 6.48 / 32.24 ) | 800 l/h N2 flushing per module |
RICH1 PD | 8 | CH4 | 100 | 320 | 300 | 60 | 32.24 ( - ) | closed circuit |
RICH1 rad | 1 | C4F10 | 100 | 800002) | normal: 5000 fast: 500003) | - 4) | - 4) | closed circuit |
sum of running cost: 269.34 per day |