COMPASS user request for test beam time (v1.0) ---------------------------------------------- ECAL1,2 ------- 1. contact person: A.Singovski 2. type of detector to be tested: Electromagnetic calorimeter 3. period foreseen for the tests: 4 x 1 week 4. do you handle with flamable gases (yes, no): no 5. longitudinal size of the detector (including frames etc): [cm]: 150 [radiation lengths]: 25 [interaction lengths]: ~1 6. transverse size of the detector [cm]: 150 7. beam energy [GeV]: 5 - 150 8. beam partciles (electrons, hadrons, muons): all 9. estimated # of events: 3*10**6/day (max) * 30 days (max) = 10**8 10.a) desired rate [particles/spill]: 2000 b) maximum tolerable rate [particle/spill]: 5000 ( PM stability ) 11. independent tracking required (yes, no): yes 12. readout electronics: GAMS ADC crate + COMPASS ADC prototype (VME64) 13. estimated amount of rack space for the readout electronics: 1 14. What is the maximum tolerable amount of material upstream your detector [radiation lengths]: 2-5 % [interaction lengths]: 0. HCAL 2 ------- 1. contact person: G.Khaoustov 2. type of detector to be tested: Hadron calorimeter 3. period foreseen for the tests: 2 x 1 week 4. do you handle with flamable gases (yes, no): no 5. longitudinal size of the detector (including frames etc): [cm]: 150 [radiation lengths]: [interaction lengths]: 5 6. transverse size of the detector [cm]: 100 7. beam energy [GeV]: 5 - 150 8. beam partciles (electrons, hadrons, muons): hadrons, muons 9. estimated # of events: 3*10**6/day (max) * 10 days (max) = 3*10**7 10.a) desired rate [particles/spill]: 2000 b) maximum tolerable rate [particle/spill]: 5000 ( PM stability ) 11. independent tracking required (yes, no): yes 12. readout electronics: GAMS ADC crate + COMPASS ADC prototype (VME64) 13. estimated amount of rack space for the readout electronics: 1 14. What is the maximum tolerable amount of material upstream your detector [radiation lengths]: 2-5 [interaction lengths]: 0.1 ECAL2-HCAL2 joint test ---------------------- 1. contact person: A.Singovski 2. type of detector to be tested: Hadropn + electromagnetic calorimeter 3. period foreseen for the tests: 1 week 4. do you handle with flamable gases (yes, no): no 5. longitudinal size of the detector (including frames etc): [cm]: 300 [radiation lengths]: 25 + a lot [interaction lengths]:6 6. transverse size of the detector [cm]: 150 7. beam energy [GeV]: 5 - 150 8. beam partciles (electrons, hadrons, muons): all 9. estimated # of events: 3*10**6/day (max) * 7 days (max) = 2*10**7 10.a) desired rate [particles/spill]: 2000 b) maximum tolerable rate [particle/spill]: 5000 ( PM stability ) 11. independent tracking required (yes, no): yes 12. readout electronics: GAMS ADC crate + COMPASS ADC prototype (VME64) 13. estimated amount of rack space for the readout electronics: 1 14. What is the maximum tolerable amount of material upstream your detector [radiation lengths]: 2-5 % [interaction lengths]: 0.