Hi Jakko, some clarifications to your summary to not propogate false informations: On Mon, 4 Jul 2005, Jaakko Henrik Koivuniemi wrote: > > Minutes from target meeting held June 30 2005 in 892-1-B09 > > a) The OD magnet solenoid was ramped up to 2.7 T with special procedure > to eliminate the broken trim coil. we do not eliminate the "shorted" trim coil, we just ensure that the induced current is 0 after having reached "homogenuous" field. > Preliminary field homogeneity of 100 ppm > has been reached. More careful field mapping is in progress. The OD magnet > safety system was tested with 400 A current. I do not understand what you mean here. The quench detection system works at any current, up to 700A. > About 3000 l of LHe is lost > in an induced quench. We have lost less than 3000l of LHe in ALL quenches induced so far (about 8). I estimate that we loose about 300 in one quench induced at 2.5 T. Regards, Claude MARCHAND.