Minutes from target meeting held May 22 2015 in 892-2-009 These minutes are available also from: http://wwwcompass.cern.ch/compass/detector/target/Minutes/2015/ a) New linux service 'ptcmd' to change instrument reading configuration in COMPASS DCS system. b) Yuri: the upstream and downstream target cells were polarized to about -0.76 and +0.76. With the preliminary thermal equilibrium calibration constants there is relatively large difference in the polarization measured by the internal coils and those mounted on the target cells. There is about 0.7 mT shift in the NMR peak positions when using negative and positive solenoid currents. This could be explained by the yoke magnetization or by some ferromagnetic material nearby. c) Fabrice: the solenoid current shift of 6 - 7 A for NMR baseline data taking has been implemented. Dipole field rotation tested successfully. First attempts to automatize baseline taking from NMR PC were done, but small problems remain. The North Magnetic Pole of both solenoid and dipole fields need to be checked with a compass or a magnetometer. d) Norihiro: update Siemens S7 300 PLC programs for run 2015.