Minutes from target meeting held October 19 2007 in 888 These minutes are available also from: http://wwwcompass.cern.ch/compass/detector/target/Minutes/2007/ a) Fabrice: Tuesday October 16 09:00 at zero field for an hour. Polarization -27 % upstream and +7 % middle cell after. Start microwave reversal 11:15. On Thursday 15:30 polarizations +91.5 %, -81.5 % and +86.6 % reached. Relaxation times in frozen spin mode in transverse 0.63 T field October 10 - 16 were 4268 h, 4234 h and 2400 h. b) Fabrice: pump helium from 4He pumping line with a small non hermetic 12 m^3/h rotary pump. The pump outlet is connected through oil mist eliminator to an oxygen analyzer. The oxygen level is practically 0 ppm, while in the recovery line after the magnet and dilution cryostat 10 - 12 ppm is normally observed. c) Mixing chamber temperature and microwave leakage were discussed. Yuri: lower polarization measured by coils 6,7 and 8 can be due to microwave leakage in the downstream stopper. Jaakko: an other explanation is better material packing at the downstream end of the target cells. d) Yuri: the NMR frequencies are shifting about 10 kHz in the beginning of the polarization. More careful analysis of this process is needed.