Minutes from target meeting held March 16 2006 in 892-1-B09 These minutes are available also from: http://wwwcompass.cern.ch/compass/detector/target/Minutes/2006/ a) The magnet was warmed with rate of 2 K/h to room temperature. Modifications to the magnet gas piping are in progress. This includes installation of the second safety valve from the SMC magnet. It was modified to lower +0.5 bar (1.5 bara) opening pressure. b) Kaori tested stability of the Q-meters in presence of stray magnetic field from the target magnet. Influence to the Q-curve was negligible. The test was done without coaxial cable going into the center of the magnet. c) Contactor for roots blower motor #7 was replaced. PTC thermistor inside the winding seems to be damaged. Temporary fix was done. d) Two summer students were selected for 2006. Their availability will be confirmed later.